ALLIED MEDITEC 707 PORTABLE MONITOR

Product Specification

Parameters MeasuredECG, RESP, NIBP, SPO2, Temperature, ETCO2, IBP, PR
Suitable ForAdult, Pediatric, Neonatal
DisplayDigital
ModelM707
Automation GradeAutomatic
Size12.1" LED
I Deal InNew Only
BrandAllied Meditec

Product Description

Features:
  • The choice of 12.1” LED color display provides superior flexibility for different clinical applications
  • Accurate monitoring of ECG, SPO2, NIBP, TEMP, RESP, HR, PR and optional IBP, EtCo2
  • Pacemaker detection, Electrosurgical interference proof
  • Defibrillation protection and defibrillation synchronization
  • OxyCRG available to judge the respiration and circular function for neonates
  • 120 hours graphic and tabular trends of all parameters
  • USB ports and SD card slot to ensure data storage/function upgrades
  • Select from either Sidestream, or Mainstream EtCO2 technology to obtain fast, simple, and accurate CO2 results
  • Nurse call function and Bi-directional communication with Central

Display:
  • Various working interface selectable: Standard Monitoring Display, Large Font Intensive Care Display, Trend Graph/ Monitoring Co-Display, Bed to Bed view Display (optional), OxyCRG Dynamic View Display, Drug Dose Calculation Interface
  • Sweep Speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s

ECG:
  • Lead Mode: 3 Leads (R, L, F or RA, LA, LL), 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)
  • Waveform: 7 waveforms display on a screen
  • 4 selectable plus: 0.25, 0.5, 1, 2 cm/mV
  • PACE detection Detection leads: 7 selectable leads: I, II, III, AVR, AVL, AVF, V
  • Defibrillation energy distributary Input voltage range ±8mV, polarized voltage: ±500mV
  • CMRR Diagnosis: >100 dB (no 50Hz/60Hz software wave trap)
  • Monitor: >110 dB (has 50Hz/60Hz software wave trap)
  • Surgery: >100dB (50Hz/60Hz software wave trap)
  • System noise: <30μV p-p (RTI)
  • HR Measuring and Alarm Range
  • Adult/Ped: 15 bpm – 300bpm
  • Neo: 15 bpm – 350bpm
  • Accuracy: ±1% or ±1bpm, which great
  • Resolution: 1 bpm
  • Sensitivity: > 200 μV P-P
  • Differential Input Impedance: ≥ 5 MΩ
  • Electrode offset potential: 300mVd.c. – 600mVd.c.
  • Patient leakage current: < 10 uA
  • ECG Signal Range: 6 mV (Vp-p).
  • ST Segment Monitoring Range Measure and Alarm: -2.0 – +2.0 mV

Respiration:
  • Method: Impedance between R-F (RA-LL), R-L (RA-LA)

Respiration Rate Measuring and Alarm Range:
  • Adult: 0 rpm – 120 rpm Neo/Ped 0 rpm – 150 rpm
  • Resolution: 1 rpm Accuracy 2 rpm
  • Gain Selection: 0.25, 0.5, 1, 2, 3, 4, 5

IBP:
  • Channel: Upto 4 channel
  • Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
  • Static Pressure Measuring Range: (-)50 – +300 mmHg (up to 350 mmHg)
  • Static Pressure Accuracy: ±2% or ±1 mmHg whichever is higher
  • Dynamical Pressure Measuring Range: (-)50 – +300 mmHg
  • Dynamical Pressure Accuracy: 2 % or 1mmHg which bigger
  • ART: 0 – 300 (mmHg) PA 6 – 120 (mmHg)
  • CVP/RAP/LAP/ICP: (-)10 – 40 (mmHg) P1/P2 (-)50 – 300 (mmHg)
  • Resolution: 1 (mmHg) Zero range 200 mmHg